Product information sheets
Start with the selected model. Share its dimensions, component choices and approximate weight with the project team.
Specifications • Utilities • Component instructions
Product information for plumbers, gas technicians and the professionals installing a Modofire feature. We provide specifications and manufacturer instructions. Your qualified team plans the site services and performs the installation.
Modofire does not provide installation services or design site gas and electrical systems.
Find your product information sheetUse a verified drawing before placing a gas stub, conduit or anchor. Contact us when the entry details for the selected model are not shown.
Start with the selected model. Share its dimensions, component choices and approximate weight with the project team.
Manufacturer installation and operating instructions. Confirm they apply to the exact burner and ignition supplied.
Manufacturer reference chart with stated supply assumptions. Your gas professional determines the pipe size for the actual run.
Current Warming Trends documents for the supplied system. Check the model and revision before installation.
Manufacturer component drawings. Select the exact model. Request custom burner drawings separately when needed.
Burner and ignition references collected in one place, including power requirements and manufacturer documents.
These guides use the same product guidance shown elsewhere on the site. The supplied manufacturer instructions govern the actual installation.
The supplied brass jet burner is matched to the selected opening. Current Modofire configurations use Warming Trends CROSSFIRE® burners with WATERSTOP® where identified in the product options.
See your selected configuration for the burner dimensions, model and maximum BTU input. Burner dimensions differ from the opening size. Custom burner figures remain approximate until the final specification is confirmed.
Natural gas and propane require the correct fuel configuration. A qualified gas professional must confirm supply pressure and capacity. Stainless steel alternatives may be available by request.
BTU input describes the gas demand at the stated conditions. It is not a promise of usable heating output. Select the feature for its setting and intended use. Follow the supplied burner instructions for clearances, ventilation and media.
Available systems depend on the selected burner and fuel. The product options identify the supplied system and any upgrades.
WT PBIK3.0 is a battery-powered push-button spark ignition. Open the side key valve and use the button to light the burner. Adjust the flame with the key valve. No site electrical service is required. This system does not automatically shut off the gas if the flame goes out.
Battery-powered push-button spark ignition with a standing pilot and safety shutoff. The system shuts off gas if the pilot flame is lost. No site electrical service is required. Available for compatible configurations up to 240,000 BTU.
A 12V electronic ignition with flame sensing and automatic relighting. The supplied transformer connects to a suitable 120V electrical supply. Use a compatible external switch or control. Available for compatible configurations up to 490,000 BTU.
A Platinum 24V package may be specified where offered for a higher-capacity burner. Its transformer also requires a suitable 120V supply. Confirm the exact package before planning electrical work.
Wi-Fi, Bluetooth and rechargeable app-control packages are not part of the current standard offering. Follow the instructions supplied with the exact ignition system for installation and operation.
Start with the selected product size, fuel, burner input and ignition system. Give the product information sheet and manufacturer instructions to your contractor before preparing site services.
A qualified gas professional must size the supply for the burner input, fuel, available pressure and total developed pipe length. Fittings and other connected appliances affect the calculation. The connection size on the feature does not determine the required site pipe size.
The chart is a planning reference with stated supply assumptions. Your installer must confirm the conditions for the actual installation. Modofire does not design the site gas system.
A qualified electrical professional must provide the required outdoor-rated service and protection. Confirm transformer placement and the manufacturer's cable limits before running wiring.
Use a verified drawing for the selected model and size. Utility entry locations can vary. If your information sheet does not show a confirmed entry location, contact Modofire before setting a gas stub, conduit or anchor.
Use only the tank arrangement specified for the selected product. Internal-tank models have model-specific requirements. A horizontal-tank design requires a purpose-built horizontal propane tank; a standard upright cylinder must not be laid on its side.
Pumps and lighting have their own electrical requirements when selected. Review their supplied specifications separately from the ignition system.