Aspen Square Fire Pit Table
- Unit price
- / per
Made to order. Shipping is charged separately. Contact us for the current production estimate; shipping and delivery dates cannot be guaranteed.
Adding product to your cart
The Aspen Square Fire Table frames the flame within a broad square tabletop. Its wood grain concrete finish gives the low form a textured surface.
Material: Archpot Concrete (glass fiber reinforced concrete).
Selected size: 42"L x 42"W x 16"H
- Dimensions
- 42"L x 42"W x 16"H
- Vessel weight
- 285 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Selected size: 48"L x 48"W x 16"H
- Dimensions
- 48"L x 48"W x 16"H
- Vessel weight
- 370 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Choose from the Archpot Concrete finishes offered for this product. Hand-applied finishes and screens can vary; confirm the finish with a physical sample.
Contact us about availability of up to five free samples. Samples can also be ordered individually when available.
The standard package includes the concrete vessel, factory stainless burner package, support plate, key valve assembly and two whistle-free flex lines. Burner and ignition upgrades are specified and priced separately. Fire media is a separate option.
Selected size: 42"L x 42"W x 16"H
- Dimensions
- 42"L x 42"W x 16"H
- Vessel weight
- 285 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Selected size: 48"L x 48"W x 16"H
- Dimensions
- 48"L x 48"W x 16"H
- Vessel weight
- 370 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
The standard stainless burner is matched to the selected vessel size. Warming Trends burner upgrades will be offered as separate options where compatible. Confirm the selected burner and fuel before installation.
Manual match-lit ignition is the standard starting configuration. Electronic ignition choices depend on the burner package. Factory stainless packages use the applicable Flame-tec system; Warming Trends upgrades use compatible Warming Trends ignition options.
Confirm the exact ignition, power requirements and accessories in your estimate. Electronic ignition is not included in the core price.
Fire glass and lava media are separate options. Use only media approved for the selected burner and follow the manufacturer installation instructions. Final quantities will be matched to the opening and burner package.
Selected size: 42"L x 42"W x 16"H
Selected size: 48"L x 48"W x 16"H
Manufacturer drawings provide size-specific references. Existing model links are retained as visual references; confirm the drawing and selected size before fabrication or installation.
Use the care and installation instructions for your Archpot Concrete vessel and the exact burner and ignition supplied with it.
- Keep ventilation and drainage openings clear.
- Use the required mounting hardware for fire bowls and follow the supplied installation instructions.
- Remove covers before operation. Allow the fire feature to cool before covering it, and remove the wind guard before fitting the fabric cover.
Archpot care and installation guides
Fire bowl mounting instructions
Warming Trends burner and ignition guidesGas and electrical planning
Start with the selected product size, fuel, burner input and ignition system. Give the product information sheet and manufacturer instructions to your contractor before preparing site services.
Gas supply
A qualified gas professional must size the supply for the burner input, fuel, available pressure and total developed pipe length. Fittings and other connected appliances affect the calculation. The connection size on the feature does not determine the required site pipe size.
Warming Trends gas pipe sizing reference
The chart is a planning reference with stated supply assumptions. Your installer must confirm the conditions for the actual installation. Modofire does not design the site gas system.
Does the ignition need electricity?
- Push-button spark: battery powered. No site electrical supply.
- Mercury: battery powered with pilot-loss safety shutoff. No site electrical supply.
- Cobalt: 12V ignition supplied through a transformer connected to a suitable 120V supply.
- Platinum, where specified: 24V ignition supplied through a transformer connected to a suitable 120V supply.
A qualified electrical professional must provide the required outdoor-rated service and protection. Confirm transformer placement and the manufacturer's cable limits before running wiring.
Where do the connections enter?
Use a verified drawing for the selected model and size. Utility entry locations can vary. If your information sheet does not show a confirmed entry location, contact Modofire before setting a gas stub, conduit or anchor.
Propane configurations
Use only the tank arrangement specified for the selected product. Internal-tank models have model-specific requirements. A horizontal-tank design requires a purpose-built horizontal propane tank; a standard upright cylinder must not be laid on its side.
Other connected components
Pumps and lighting have their own electrical requirements when selected. Review their supplied specifications separately from the ignition system.
Burner and ignition installation manual • Installation resources
Set the scene, then copy a prompt or choose an AI tool.
Describe your scene in the optional detail below.
Uses your selected product options and photos.More options
OutputUse Selected OptionsUse Product PhotosApply These AdjustmentsPlanFrontIsometricDimensionsFor a CAD-capable assistant. Product photos and selected dimensions guide a conceptual model; construction details still need review.
For best consistency, attach an approved product render as the starting image in your video tool. This prepares a prompt; video is created there.
View or edit prompt
Selected product details
Ready to copy.
AI concepts are for review. Confirm product details before ordering.
Current shipping details
Archpot concrete products are made to order and ship from the manufacturer's facility in Corona, California, unless your order states otherwise.
Timing and freight
Production, shipping and delivery dates are estimates and cannot be guaranteed. Confirm the current production estimate before ordering. Carrier scheduling and transit conditions can affect arrival.
Shipping is charged separately at checkout using our fixed freight rates for the contiguous United States. These are Modofire's shipping charges, not a live carrier quote. Freight service is curbside; placement, uncrating, assembly and installation are not included. Residential delivery, liftgate availability and unloading requirements must be coordinated before dispatch. Large crates may require suitable unloading equipment. Contact us before ordering for delivery outside the contiguous United States or special access requirements. Vessel weights exclude the shipping crate and packing.
Inspect your delivery
Inspect the crate before signing. If it is damaged, do not accept the shipment; contact Modofire and the carrier immediately. Photograph the crate and delivery paperwork.
For an intact crate, carefully open the top and check the product for damage, correct size, shape and finish. Photograph the unpacking process and report damage or an incorrect product to Modofire within 72 hours. Keep the crate and all packaging intact until the issue is resolved. Any authorized return must use the undamaged original crate.
After confirming the order is correct and undamaged, remove the remaining packaging within 72 hours and follow the handling instructions.
Archpot receiving, handling and care instructions · Contact Modofire
These manufacturer warranties apply to Archpot products supplied by Modofire. Coverage follows the individual component and the approved installation.
Component Residential Commercial Archpot GFRC vessel and finish 3 years 2 years Archpot stainless steel burner and support plate 3 years 2 years Warming Trends brass burner Lifetime manufacturer warranty Lifetime manufacturer warranty Flame-tec Weather Beater electronic ignition 2 years 1 year Warming Trends Mercury ignition 3 years 1 year Warming Trends Cobalt ignition 3 years 1 year Battery push-button spark kit Confirm coverage for the supplied Archpot assembly before ordering. Fire by Design AWEIS, where supplied 3 years 1 year Archpot coverage begins on the original purchase date. Weather Beater coverage begins on the documented installation date, or its manufacture date if installation is not documented. Warming Trends and Fire by Design periods begin on the purchase date. Lifetime coverage applies to the brass burner only.
Installation and care
Follow the instructions for the exact vessel, burner and ignition. Use the required mounting hardware, preserve ventilation and drainage, use approved media, and fit the specified wind guard where required for the model. Protect the cooled fire feature when not in use and remove covers before operation. Ignition coverage depends on the approved burner, plate or pan, accessories and cover.
These warranties generally exclude installation or service labor, removal, reinstallation, inspection and freight, as specified by the component manufacturer. Damage from misuse, modification, incorrect installation or maintenance is excluded.
Warranty assistance
Contact Modofire with your order reference, installation date, component model and photographs before returning any item. We will help coordinate the manufacturer's review. Repair or replacement is subject to its written warranty; this summary does not expand that coverage.
Archpot component warranties · Current Archpot vessel and finish coverage · Required bowl mounting · Warming Trends ignition warranty guide
Archpot vessels and fire features are made to order. They are not eligible for a change-of-mind return after shipment.
Before shipment
Contact Modofire promptly if you need to cancel or change an order. Cancellation depends on the manufacturer's production status and requires approval. Archpot's production deposit becomes non-refundable once production starts. Any approved refund must account for committed supplier costs and work already completed.
Damage, defects or an incorrect item
These issues follow the receiving or warranty process rather than a standard return. Report shipping damage or an incorrect product within 72 hours of delivery, with photographs, and keep the original crate and packaging. Contact Modofire before sending anything back. Manufacturer authorization is required for a replacement or return, and additional packing or freight charges may apply.
Warranty claims follow the terms for the affected component. This policy does not limit rights that cannot be excluded by law.
Archpot receiving and return instructions · Contact Modofire
The Aspen Square Fire Table frames the flame within a broad square tabletop. Its wood grain concrete finish gives the low form a textured surface.
Material: Archpot Concrete (glass fiber reinforced concrete).
Selected size: 42"L x 42"W x 16"H
- Dimensions
- 42"L x 42"W x 16"H
- Vessel weight
- 285 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Selected size: 48"L x 48"W x 16"H
- Dimensions
- 48"L x 48"W x 16"H
- Vessel weight
- 370 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Choose from the Archpot Concrete finishes offered for this product. Hand-applied finishes and screens can vary; confirm the finish with a physical sample.
Contact us about availability of up to five free samples. Samples can also be ordered individually when available.
The standard package includes the concrete vessel, factory stainless burner package, support plate, key valve assembly and two whistle-free flex lines. Burner and ignition upgrades are specified and priced separately. Fire media is a separate option.
Selected size: 42"L x 42"W x 16"H
- Dimensions
- 42"L x 42"W x 16"H
- Vessel weight
- 285 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
Selected size: 48"L x 48"W x 16"H
- Dimensions
- 48"L x 48"W x 16"H
- Vessel weight
- 370 lb
- Standard burner
- Stainless Steel Spoke Burner 18in
- Heat output
- 125000 BTU
The standard stainless burner is matched to the selected vessel size. Warming Trends burner upgrades will be offered as separate options where compatible. Confirm the selected burner and fuel before installation.
Manual match-lit ignition is the standard starting configuration. Electronic ignition choices depend on the burner package. Factory stainless packages use the applicable Flame-tec system; Warming Trends upgrades use compatible Warming Trends ignition options.
Confirm the exact ignition, power requirements and accessories in your estimate. Electronic ignition is not included in the core price.
Fire glass and lava media are separate options. Use only media approved for the selected burner and follow the manufacturer installation instructions. Final quantities will be matched to the opening and burner package.
Selected size: 42"L x 42"W x 16"H
Selected size: 48"L x 48"W x 16"H
Manufacturer drawings provide size-specific references. Existing model links are retained as visual references; confirm the drawing and selected size before fabrication or installation.
Use the care and installation instructions for your Archpot Concrete vessel and the exact burner and ignition supplied with it.
- Keep ventilation and drainage openings clear.
- Use the required mounting hardware for fire bowls and follow the supplied installation instructions.
- Remove covers before operation. Allow the fire feature to cool before covering it, and remove the wind guard before fitting the fabric cover.
Archpot care and installation guides
Fire bowl mounting instructions
Warming Trends burner and ignition guides
Gas and electrical planning
Start with the selected product size, fuel, burner input and ignition system. Give the product information sheet and manufacturer instructions to your contractor before preparing site services.
Gas supply
A qualified gas professional must size the supply for the burner input, fuel, available pressure and total developed pipe length. Fittings and other connected appliances affect the calculation. The connection size on the feature does not determine the required site pipe size.
Warming Trends gas pipe sizing reference
The chart is a planning reference with stated supply assumptions. Your installer must confirm the conditions for the actual installation. Modofire does not design the site gas system.
Does the ignition need electricity?
- Push-button spark: battery powered. No site electrical supply.
- Mercury: battery powered with pilot-loss safety shutoff. No site electrical supply.
- Cobalt: 12V ignition supplied through a transformer connected to a suitable 120V supply.
- Platinum, where specified: 24V ignition supplied through a transformer connected to a suitable 120V supply.
A qualified electrical professional must provide the required outdoor-rated service and protection. Confirm transformer placement and the manufacturer's cable limits before running wiring.
Where do the connections enter?
Use a verified drawing for the selected model and size. Utility entry locations can vary. If your information sheet does not show a confirmed entry location, contact Modofire before setting a gas stub, conduit or anchor.
Propane configurations
Use only the tank arrangement specified for the selected product. Internal-tank models have model-specific requirements. A horizontal-tank design requires a purpose-built horizontal propane tank; a standard upright cylinder must not be laid on its side.
Other connected components
Pumps and lighting have their own electrical requirements when selected. Review their supplied specifications separately from the ignition system.
Burner and ignition installation manual • Installation resources
Set the scene, then copy a prompt or choose an AI tool.
Describe your scene in the optional detail below.
More options
For a CAD-capable assistant. Product photos and selected dimensions guide a conceptual model; construction details still need review.
For best consistency, attach an approved product render as the starting image in your video tool. This prepares a prompt; video is created there.
View or edit prompt
Selected product details
Ready to copy.
AI concepts are for review. Confirm product details before ordering.
Current shipping details
Archpot concrete products are made to order and ship from the manufacturer's facility in Corona, California, unless your order states otherwise.
Timing and freight
Production, shipping and delivery dates are estimates and cannot be guaranteed. Confirm the current production estimate before ordering. Carrier scheduling and transit conditions can affect arrival.
Shipping is charged separately at checkout using our fixed freight rates for the contiguous United States. These are Modofire's shipping charges, not a live carrier quote. Freight service is curbside; placement, uncrating, assembly and installation are not included. Residential delivery, liftgate availability and unloading requirements must be coordinated before dispatch. Large crates may require suitable unloading equipment. Contact us before ordering for delivery outside the contiguous United States or special access requirements. Vessel weights exclude the shipping crate and packing.
Inspect your delivery
Inspect the crate before signing. If it is damaged, do not accept the shipment; contact Modofire and the carrier immediately. Photograph the crate and delivery paperwork.
For an intact crate, carefully open the top and check the product for damage, correct size, shape and finish. Photograph the unpacking process and report damage or an incorrect product to Modofire within 72 hours. Keep the crate and all packaging intact until the issue is resolved. Any authorized return must use the undamaged original crate.
After confirming the order is correct and undamaged, remove the remaining packaging within 72 hours and follow the handling instructions.
Archpot receiving, handling and care instructions · Contact Modofire
These manufacturer warranties apply to Archpot products supplied by Modofire. Coverage follows the individual component and the approved installation.
| Component | Residential | Commercial |
|---|---|---|
| Archpot GFRC vessel and finish | 3 years | 2 years |
| Archpot stainless steel burner and support plate | 3 years | 2 years |
| Warming Trends brass burner | Lifetime manufacturer warranty | Lifetime manufacturer warranty |
| Flame-tec Weather Beater electronic ignition | 2 years | 1 year |
| Warming Trends Mercury ignition | 3 years | 1 year |
| Warming Trends Cobalt ignition | 3 years | 1 year |
| Battery push-button spark kit | Confirm coverage for the supplied Archpot assembly before ordering. | |
| Fire by Design AWEIS, where supplied | 3 years | 1 year |
Archpot coverage begins on the original purchase date. Weather Beater coverage begins on the documented installation date, or its manufacture date if installation is not documented. Warming Trends and Fire by Design periods begin on the purchase date. Lifetime coverage applies to the brass burner only.
Installation and care
Follow the instructions for the exact vessel, burner and ignition. Use the required mounting hardware, preserve ventilation and drainage, use approved media, and fit the specified wind guard where required for the model. Protect the cooled fire feature when not in use and remove covers before operation. Ignition coverage depends on the approved burner, plate or pan, accessories and cover.
These warranties generally exclude installation or service labor, removal, reinstallation, inspection and freight, as specified by the component manufacturer. Damage from misuse, modification, incorrect installation or maintenance is excluded.
Warranty assistance
Contact Modofire with your order reference, installation date, component model and photographs before returning any item. We will help coordinate the manufacturer's review. Repair or replacement is subject to its written warranty; this summary does not expand that coverage.
Archpot component warranties · Current Archpot vessel and finish coverage · Required bowl mounting · Warming Trends ignition warranty guide
Archpot vessels and fire features are made to order. They are not eligible for a change-of-mind return after shipment.
Before shipment
Contact Modofire promptly if you need to cancel or change an order. Cancellation depends on the manufacturer's production status and requires approval. Archpot's production deposit becomes non-refundable once production starts. Any approved refund must account for committed supplier costs and work already completed.
Damage, defects or an incorrect item
These issues follow the receiving or warranty process rather than a standard return. Report shipping damage or an incorrect product within 72 hours of delivery, with photographs, and keep the original crate and packaging. Contact Modofire before sending anything back. Manufacturer authorization is required for a replacement or return, and additional packing or freight charges may apply.
Warranty claims follow the terms for the affected component. This policy does not limit rights that cannot be excluded by law.
Archpot receiving and return instructions · Contact Modofire